WorldCat Identities

Vannier, Jean-Claude

Overview
Works: 42 works in 60 publications in 2 languages and 73 library holdings
Roles: Thesis advisor, Opponent, Other, Author
Publication Timeline
.
Most widely held works by Jean-Claude Vannier
CONTRIBUTION A LA DEFINITION DE STRUCTURES OPTIMALES D'ONDULEURS POUR LA COMMANDE DE MACHINES A COURANT ALTERNATIF PAR DTC by Miguel F Escalante Gutierrez( Book )

3 editions published in 2001 in French and held by 5 WorldCat member libraries worldwide

CE TRAVAIL EST UNE CONTRIBUTION A LA DEFINITION D'UN ONDULEUR MULTINIVEAUX POUR LA COMMANDE DE MACHINES A COURANT ALTERNATIF PAR LA METHODE DE LA COMMANDE DIRECTE DE COUPLE (DTC). ON PRESENTE ICI LES DIFFERENTES STRUCTURES MULTINIVEAUX AINSI QUE LES CONTRAINTES IMPOSEES PAR UNE COMMANDE DE TYPE DTC. LORS D'UNE COMMANDE DE TYPE DTC, CHAQUE BRAS DE L'ONDULEUR MULTINIVEAUX DOIT ETRE COMMANDE AFIN D'IMPOSER LE VECTEUR TENSION DEMANDE PAR LA BOUCLE DE CONTROLE DTC. LA COMMANDE DE LA STRUCTURE MULTINIVEAUX DOIT ASSURER DEUX CONSIGNES, A SAVOIR, LA TENSION AUX BORNES DES CONDENSATEURS ET LE NIVEAU DE TENSION DEMANDE EN SORTIE. DANS CE TRAVAIL, UNE METHODE DE COMMANDE BASEE SUR LA REDONDANCE DES ETATS DE LA STRUCTURE MULTICELLULAIRE SERIE EST DEVELOPPEE ET APPLIQUEE SUR UNE STRUCTURE A 5 NIVEAUX. A LA DIFFERENCE DES METHODES DE COMMANDE TRADITIONNELLES, BASEES SUR UNE MODULATION MLI, CETTE METHODE AGIT DIRECTEMENT SUR LES ETATS DE LA STRUCTURE, ET NON PAS SUR LES RAPPORTS CYCLIQUES, POUR ASSURER LES DEUX CONSIGNES. L'APPROCHE PROPOSEE EST VALIDEE PAR L'ASSOCIATION DE L'ONDULEUR MULTINIVEAUX AVEC UNE MACHINE ASYNCHRONE COMMANDEE SELON LE PRINCIPE DE LA DTC. TROIS TYPES DE COMMANDE DTC MULTINIVEAUX SONT PROPOSEES. LES RESULTATS DE SIMULATION CONFIRMENT LA VALIDITE DES METHODES PROPOSEES. L'EQUILIBRAGE DES TENSIONS AUX BORNES DES CONDENSATEURS FLOTTANTS AINSI QUE LE VECTEUR TENSION DEMANDE PAR LA STRATEGIE DTC SONT ASSURES. PAR AILLEURS, LES STRATEGIES DTC MULTINIVEAUX REDUISENT LES ONDULATIONS DU COUPLE ELECTROMAGNETIQUE ET LE GRADIENT DE TENSION APPLIQUE A LA MACHINE. LA REALISATION D'UN PROTOTYPE DE LABORATOIRE ILLUSTRE LA FAISABILITE DES ALGORITHMES PROPOSES. LES DIFFERENTES PARTIES DU PROTOTYPE SONT PRESENTEES
CONCEPTION DE MOTORISATION D'AUXILIAIRES DANS L'AUTOMOBILE PAR MOTEUR RECYCLABLE A COMMUTATION ELECTRONIQUE by Lionel Muron( Book )

3 editions published in 1997 in French and held by 5 WorldCat member libraries worldwide

POUR SATISFAIRE LES FUTURES NORMES DE PROTECTION DE L'ENVIRONNEMENT, LE SECTEUR AUTOMOBILE DOIT ASSURER LE RECYCLAGE DES MATERIAUX CONSTITUANT UN VEHICULE. OR, LA PRESENCE TOUJOURS CROISSANTE DE PETITS MOTEURS ELECTRIQUES A BOBINAGE EN CUIVRE PENALISE LA REUTILISATION DE L'ACIER RECYCLE DANS SA FILIERE D'ORIGINE PAR SUITE D'UN POURCENTAGE DE CUIVRE SUPERIEUR AUX NORMES INDUSTRIELLES. LE TRAVAIL DE THESE PROPOSE LA CONCEPTION D'UN MOTOREDUCTEUR A COMMUTATION ELECTRONIQUE DE FAIBLE PUISSANCE POUR L'APPLICATION LEVE-VITRE UTILISANT DES MATERIAUX DE TYPE RECYCLABLE TELS QUE LE CONDUCTEUR EN ALUMINIUM. LE CHOIX D'UN MOTEUR SANS BALAI FACILITE LA FIABILISATION DE LA LIAISON COMPLEXE ENTRE LE FIL ALUMINIUM ET LE CONNECTEUR EN CUIVRE. LA CONCEPTION DE CETTE MOTORISATION PASSE PAR L'ETUDE PREALABLE DES DIFFERENTES STRUCTURES ENVISAGEABLES POUR LE MOTEUR, LE REDUCTEUR ET L'ELECTRONIQUE. DEUX CONFIGURATIONS GEOMETRIQUES, L'UNE ALLONGEE ET L'AUTRE PLATE, ONT ETE ETUDIEES ET COMPAREES AFIN DE SATISFAIRE L'ENCOMBREMENT CONTRAIGNANT DE L'APPLICATION. LA SOLUTION ALLONGEE ASSOCIANT UN MOTEUR A SECTION DISSYMETRIQUE, UN REDUCTEUR A VIS TANGENTE ET UN CONVERTISSEUR TRIPHASE UNIDIRECTIONNEL EN COURANT A PRESENTE LE MEILLEUR COMPROMIS. POUR MINIMISER LES PERTURBATIONS ELECTROMAGNETIQUES, UNE TECHNIQUE DE COMMUTATION PAR SUPERPOSITION DES COURANTS DE PHASE EST IMPLEMENTEE UTILISANT UN CONTROLE LINEAIRE DU COURANT TRAVERSANT CHAQUE INTERRUPTEUR. LE BRUIT MAGNETIQUE AUDIBLE EST EGALEMENT REDUIT PAR LA DEFINITION D'UNE SECTION OPTIMALE MINIMISANT LE COUPLE DE DETENTE DANS L'ENTREFER. FINALEMENT, LA RECYCLABILITE DU MOTOREDUCTEUR CHOISI ETANT ASSUREE PAR L'UTILISATION D'UN CONDUCTEUR EN ALUMINIUM, UNE METHODE EXPERIMENTALE EST ADOPTEE POUR LA DEFINITION D'UNE SOUDURE ELECTROMECANIQUE FIABLE SUR UN CONNECTEUR EN CUIVRE
Modélisation et optimisation d'un moteur à très faible inertie by Mohamed Mnassri( )

2 editions published in 1989 in French and held by 5 WorldCat member libraries worldwide

L'étude présentée dans ce domaine a permis d'apporter une contribution à la modélisation des machines électriques spéciales. Il s'agit ici d'un moteur synchrone à aimants permanents, à réductance variable, à rotor oscillant et de très faible inertie. Dans ce moteur, le rotor a un mouvement de translation circulaire qui communique un mouvement de rotation à l'arbre par l'intermédiaire d'excentriques; le moteur a ainsi un très faible moment d'inertie. Les accélérations angulaires sur l'arbre sont alors extrèmement importantes. Un modèle analytique puis un modèle numérique ont été mis au point afin d'analyser le principe de fonctionnement de ce moteur et de rechercher ses performances optimales. Cette étude a débuté par la présentaiton de la structure du moteur. Nous avons ensuite décrit son fonctionnement original tant sur le plan mécanique que sur le plan magnétique. Dans le but d'avoir une première approche du comportement de ce moteur, un modèle linéaire a été établi. Les éléments constructifs de ce modèle sont déterminés un par un et en particulier les variations de la perméance d'entrefer en fonction de la position du rotor. Dans une seconde étape, saturation et flux de fuite sont pris en compte pour établir un nouveau modèle. En raison de la non-linéarité de certains de ses éléments, la résolution est conçue par un programme informatique. Le point de fonctionnement est déterminé itérativement. La validité du modèle a été vérifiée par la mesure des flux, des F.E.M. et du couple sur un prototype. Une nouvelle simulation numérique basée sur la méthode des éléments finis et appliquée à une coupe transversale du moteur a été élaborée. Enfin la dernière partie concerne l'optimisation de ce moteur. Notre principal objectif est d'améliorer l'inertie et le couple. Ainsi la forme de la tôle du stator, l'influence du nombre d'aimants, de lentraxe et de l'entrefer minimum ont été étudiées
Transfert sous vide de Hautes Puissances Pulsées par utilisation du phénomène d'isolement magnétique by Isabelle Magne( Book )

2 editions published in 2000 in French and held by 4 WorldCat member libraries worldwide

Modélisation et commande non linéaire des hydroliennes couplées à un réseau électrique by Mamadou Dansoko( Book )

3 editions published in 2014 in French and held by 4 WorldCat member libraries worldwide

This thesis develops nonlinear and robust control strategies in order to ensure a successful connection of marine turbine systems into grid. In addition, it is a question to examine in simulation and practice the dynamic behavior of controlled marine turbine systems under severe perturbations. Firstly, we have modeled all production chain elements of marine turbine system. Secondly, we have proposed three nonlinear control strategies ; one for marine turbine system single machine connected to infinite bus and the both others for two multimachine electrical networks. The developed strategies control stability is proven mathematically by using Lyapunov method and one specific property of variable structure. These strategies control particularity is the two outputs regulation (terminal voltage and frequency) trough a single input (synchronous machine excitation). Finally, simulation results under mechanical and electrical perturbations are presented in order to highlight the robustness qualities of the proposed controllers compared to nonlinear controller CNL and classical AVR-PSS. In view of industrial applications, the proposed control for marine turbine single machine system is implemented on experimental bench. The obtained practical results under hard perturbations are very satisfactory. These results are used to realize a comparative study between the proposed control, the CNL and the AVR-PSS
CONTRIBUTION A LA MISE EN ŒUVRE D'UN OUTIL D'OPTIMISATION ET DE DIMENSIONNEMENT D'UN ACTIONNEUR LINEAIRE by MOSTAFA KADIRI( Book )

2 editions published in 2000 in French and held by 3 WorldCat member libraries worldwide

NOUS SAVONS QUE LES MACHINES TOURNANTES ONT FINI PAR S'IMPOSER. MAIS IL EXISTE DE NOMBREUSES APPLICATIONS OU LES ACTIONNEURS LINEAIRES RESTENT TRES PRESENTS ET CONCURRENCENT EFFICACEMENT LES DISPOSITIFS ASSOCIANT MOTEURS ROTATIFS ET MECANISMES DE TRANSFORMATION. L'EVOLUTION GENERALE DE LA TECHNIQUE ALLANT VERS UN BESOIN DE RAPIDITE, ON DEMANDE DE PLUS EN PLUS A CES ACTIONNEURS D'AVOIR UNE FORCE IMPORTANTE. L'OBJET DE NOTRE TRAVAIL, CONCERNE LES ACTIONNEURS LINEAIRES DE TYPE VENTOUSE. TOUTE MACHINE A RELUCTANCE VARIABLE PURE (SANS POLARISATIONS DU CIRCUIT MAGNETIQUE) EST CONSTITUEE DE DEUX PARTIES EN MOUVEMENT RELATIF DONT L'UNE EST ELECTRIQUEMENT ACTIVE ET L'AUTRE PASSIVE. NOTRE ACTIONNEUR LINEAIRE QUI SERA ETUDIE ET ANALYSE S'INSCRIT DANS CETTE CATEGORIE. DANS LE PREMIER CHAPITRE NOUS TRAITONS LE MODELE ELECTROMAGNETIQUE. NOUS RAPPELONS QUELQUES BASES DE CE MODELE ET NOUS PRESENTONS NOTRE METHODE D'APPROCHE. UN MODELE DE PERTES EST ENSUITE PROPOSE. LE SECOND CHAPITRE PRESENTE LE DEVELOPPEMENT D'UN OUTIL DE SIMULATION DU COMPORTEMENT ELECTROMAGNETIQUE DE L'ACTIONNEUR LINEAIRE. CE SIMULATEUR EST BASE SUR UN MODELE DE LA BOBINE ET SUR UN MODELE MECANIQUE DU RESSORT. LE SIMULATEUR TIENT COMPTE DE LA REPARTITION DES LIGNES DE CHAMPS DANS L'ENTREFER. LE MODELE THERMIQUE CONCU DANS LE TROISIEME CHAPITRE EST BASE SUR LA METHODE NODALE. UN MODELE SIMPLE EST PROPOSE ET MIS EN ŒUVRE EXPERIMENTALEMENT. NOUS PRESENTONS LES DIFFERENTES DEMARCHES UTILISEES POUR ABOUTIR A UN PROCESSUS DE CALCUL DES PARAMETRES DE CE MODELE. LE QUATRIEME CHAPITRE DEVELOPPE UN PROCESSUS DE CARACTERISATION DU MATERIAU. IL PREND EN COMPTE LA PRESENCE D'UN ENTREFER SUPPLEMENTAIRE. DES IDENTIFICATIONS PAR MODELES NUMERIQUES (MEF) BASEES SUR LA COURBE D'AIMANTATION NORMALE ONT ETE OBTENUES. LA PARTIE CONCERNANT L'OPTIMISATION PROPREMENT DITE PART D'UN MODELE INITIAL, POUR PRESENTER UN MODELE PERMETTANT D'AMELIORER LA FORCE EXERCEE SUR L'ARMATURE MOBILE SANS PERTES SUPPLEMENTAIRES. AFIN D'AMELIORER L'EVOLUTION DE LA FORCE DEVELOPPEE PAR L'ACTIONNEUR, NOUS AVONS PROCEDE SUCCESSIVEMENT A LA VARIATION DE CERTAINS PARAMETRES GEOMETRIQUES INDEPENDAMMENT LES UNS DES AUTRES AFIN DE MIEUX CERNER LES INFLUENCES RESPECTIVES, OU SIMULTANEMENT EN GARDANT LES VALEURS LES PLUS BENEFIQUES. LE MODELE DEVELOPPANT LA PLUS IMPORTANTE FORCE A PU ETRE TROUVE
Modélisation du développement à long terme du stockage de l'électricité dans le système énergétique global by Jacques Després( )

1 edition published in 2015 in English and held by 2 WorldCat member libraries worldwide

The current development of wind and solar power sources calls for an improvement of longtermenergy models. Indeed, high shares of variable wind and solar productions have shortandlong-term impacts on the power system, requiring the development of flexibility options:fast-reacting power plants, demand response, grid enhancement or electricity storage. Ourfirst main contribution is the modelling of electricity storage and grid expansion in the POLESmodel (Prospective Outlook on Long-term Energy Systems). We set up new investmentmechanisms, where storage development is based on several combined economic values.After categorising the long-term energy models and the power sector modelling tools in acommon typology, we showed the need for a better integration of both approaches.Therefore, the second major contribution of our work is the yearly coupling of POLES to ashort-term optimisation of the power sector operation, with the European Unit CommitmentAnd Dispatch model (EUCAD). The two-way data exchange allows the long-term coherentscenarios of POLES to be directly backed by the short-term technical detail of EUCAD. Ourresults forecast a strong and rather quick development of the cheapest flexibility options: gridinterconnections, pumped hydro storage and demand response programs, including electricvehicle charging optimisation and vehicle-to-grid storage. The more expensive batterystorage presumably finds enough system value in the second half of the century. A sensitivityanalysis shows that improving the fixed costs of batteries impacts more the investments thanimproving their efficiency. We also show the explicit dependency between storage andvariable renewable energy sources
Étude du problème inverse en électromagnétisme en vue de la localisation des défauts de désaimantation dans les actionneurs à aimants permanents by Jawad Ahmed Farooq( Book )

1 edition published in 2008 in French and held by 2 WorldCat member libraries worldwide

Cette thèse a porté sur la modélisation des machines synchrones à aimants permanents (MSAP) lors des régimes de fonctionnements défaillants. Deux défauts fréquents ont été étudiés : la désaimantation des aimants et le court-circuit entre spires. L'objectif est de développer des modèles aidant à la compréhension de ces phénomènes dans l'optique de réaliser des opérations de diagnostic. Concernant le défaut de désaimantation, deux modèles ont été développés. Le premier est de type analytique et est basé sur la résolution des équations de Maxwell. Le deuxième modèle, a été développé à l'aide d'un réseau de perméances équivalent (RDPE). L'étude comparative entre ces derniers a montré que le modèle du RDPE est plus précis que le modèle analytique. Pour le défaut de court-circuit entre spires dans les MSAP, un modèle dynamique a été développé. Les résultats de simulation montrent qu'un court-circuit entre spires produit un harmonique d'ordre 3 dans les courants. En se basant sur les modèles de la désaimantation, une technique de détection de défaut des aimants a été mise en œuvre. Il s'agit d'une méthode d'identification fondée sur un algorithme qui utilise comme entrées les données d'une grandeur électromagnétique telle que la FEM, pour chercher itérativement la distribution de l'induction rémanente des aimants. Une maquette expérimentale a été également mise en place afin de valider les résultats obtenus. Des essais expérimentaux sur les défauts de court-circuit ont été réalisés sur une MSAP. Les mesures étaient en bonne corrélation avec ceux donnés par le modèle et par des simulations éléments finis. Il reste à conduire des mesures sur une machine présentant le défaut de désaimantation
Impact de la pollution harmonique sur les matériels de réseau by Wilfried Frelin( Book )

2 editions published in 2009 in French and held by 2 WorldCat member libraries worldwide

The proliferation of non linear loads on power grids causes an increase of harmonic distortion. Those non linear loads connected on industrial and public networks are based on power electronics and use non sinusoidal currents. Harmonics produce by these non linear loads will impact all materials connected on power grids, instantly or on the long view. The aim of this thesis is to quantify the impact of harmonics on power grid materials. The literature study performed at the beginning of thesis concludes that two materials have to be studied more accurately: the cables in low voltage distribution grid and the transformers. The first part deals with the impact of harmonics on the thermal behavior of low voltage cables. As low voltage cables with neutral conductor allow the circulation of third harmonic, they are treated with a special attention. A finite elements model, that combines the electromagnetic and the thermal behavior, is set up. The simulation results are compared with experimental measurements. In the second part, a theoretical model of the transformer winding resistance is developed. This analytical expression allows the estimation of the winding losses in presence of harmonics. The model is experimentally verified. The thermal behavior of transformers in presence of harmonics is then shown by simulations and measurements. A discussion about the harmonic impact on the lifetime finishes the works on transformers
Les groupes d'entreprises en France : stratégie et structures by Jean-Claude Vannier( )

2 editions published between 1978 and 2019 in French and held by 2 WorldCat member libraries worldwide

Improved fault localization method for electrical power distribution networks by Raphaël Marguet( )

1 edition published in 2015 in English and held by 2 WorldCat member libraries worldwide

This thesis proposes to improve fault localization methods for electricalpower distribution networks. Transmission networks were quickly equipped with protectionand fault localization equipments. Indeed, faults on the transmission network need tobe dealt with quickly in order to avoid serious consequences. Unlike transmission networks,distribution networks have a minimal protection scheme. The smart grid developmentsbring new possibilities with the installation of new equipments giving access to many newvariables. The work presented in this thesis develop two fault localization method. Thefirst aims in using the equipment already installed (fault indicators) in order to isolatequickly and efficiently the zone concerned by the fault. The second method performs aprecise localization (in distance) of the different possible fault locations from the electricalmeasurements made on the network
Modélisation stochastique des réseaux de distribution sous incertitude by Wendy Carolina Briceño Vicente( )

1 edition published in 2012 in French and held by 2 WorldCat member libraries worldwide

Les évolutions récentes des systèmes électriques comme conséquence de la dérégulation du marché et des traités internationaux comme le protocole de Kyoto ont des répercussions importantes sur les réseaux, en particulier, ceux de distribution. En effet, une large part de la production décentralisée est prévue d'être raccordée sur ces derniers. La production décentralisée utilise des sources d'énergie renouvelables hautement imprévisibles et reparties dans la nature. Ce fait ajoute une contrainte forte sur la planification et l'exploitation des réseaux de distribution qui n'ont pas été conçus, à l'origine, pour accueillir de la production d'énergie à large échelle. Ce travail de thèse étudie l'impact de l'incertitude sur les études classiques de planification des réseaux électriques. Les études statiques et dynamiques du réseau ont été réalisées prenant en compte plusieurs sources d'incertitude dans plusieurs réseaux de distribution. Les incertitudes sont modélisées dans les études statiques par les méthodes probabilistes et possibilistes. La méthode possibilistes offre des avantages sur la méthode probabiliste. Il est déterminé le taux de pénétration éolien maximum d'un petit réseau maillé en utilisant la méthode probabiliste, ainsi que les simulations de stabilité dynamique et statique du réseau
Formalisme pour la supervision des systèmes hybrides multi-sources de générateurs d'énergie répartie : application à la gestion d'un micro réseau by Peng Li( Book )

2 editions published in 2009 in French and held by 2 WorldCat member libraries worldwide

A microgrid is a promising future network architecture which is coupling the various generators and consumers in a distribution network. This hybrid multi-source system is composed of at least one conventional generation unit and possibly a storage unit and/or a production unit based on renewable energies. Using this structure allows an immediate minimization of the losses by the energy transport, a greater reliability of power delivery and an ability to provide a high power quality energy. In this paper, we study a microgrid based on the use of a micro gas turbine, a photovoltaic array and supercapacitors. All these sources are coupled to the microgrid by power electronic converters and are interconnected to a microgrid central controller. Some local controllers and the microgrid central controller are used for the studied microgrid to achieve its operation optimization. Therefore, the first part of this thesis is devoted to establish a formalism method for a systematic design of local controllers. The second part of this thesis is devoted to the management of all these production and storage units, in order to optimize the microgrid operating. Simulation and testing results validate our design of the microgrid controllers
Micro-réseau résilient à haute stabilité dynamique en présence d'une intégration massive des énergies renouvelables variables by Kevin Banjar nahor( )

1 edition published in 2019 in English and held by 2 WorldCat member libraries worldwide

This thesis deals with the stability issues introduced by the interconnection of massive renewables into an isolated microgrid. This research aims to identify the problems related to the topic, the indices to help understand the issues, and the strategy to enhance microgrid stability from the power system point of view.In the first part, a state of the art on the evolution of power stability is addressed. A short history of power system stability since its first identification and how it has evolved is firstly presented. This part also provides a literature review of the power system stability, including its classification, and how it has evolved due to two reasons: the microgrid concept and the trend towards the integration of more inverter-based generation. A review of the practical indices for grid stability assessment is also reported, including the ones that we propose. This part is also useful for analyzing the positioning of this PhD research.The second part of thesis presents the efforts to enhance the dynamic stability of microgrids characterized by massive renewable penetration. The main challenges and the current efforts are reviewed, which have shown that the current solutions focus on maintaining the philosophy of a classical power grid. With the advent of more intermittent energy, the current efforts have proven to be costly. Therefore, a new perspective is proposed. Here, the generating elements and the customers are exposed with higher deviations in voltage and frequency, which are necessary so that that the power equilibrium and the stability of the microgrid can be maintained. This perspective is suitable with the microgrid concept to realize the dream of universal electricity.The concept is then developed into a novel regulation strategy in which the system frequency and voltage are maintained in such a way to keep their ratio essentially constant around 1 (p.u. voltage to p.u. frequency). This strategy can potentially be implemented on all grid forming technologies. The benefits of employing this strategy include assurance that the electrical machinery is not harmed, plug-and-play feature, compatibility with current grid-tied inverter technologies, and no need for fast communication systems. Finally, this proposed strategy is easy to implement and does not require revolution in terms of power system equipment and control. This implementation of this concept provides a very valuable piece of flexibility: time, which enhances the resilience and stability of a microgrid. However, wider frequency and voltage deviations occur and have to be accepted by all the actors within the microgrid. A validation through computer simulations in Power Factory and real-time hardware in the loop experiments has been carried out with satisfactory results
Optimalité des éléments d'un système décentralisé de production d'énergie électrique by Dario Morales Figureroa( Book )

2 editions published in 2006 in French and held by 2 WorldCat member libraries worldwide

Enjeux de flexibilité liés au développement des infrastructures réseaux pour l'intégration massive des énergies renouvelables variables dans le système électrique à l'horizon 2100 by Stéphane Allard( )

1 edition published in 2018 in French and held by 2 WorldCat member libraries worldwide

The power system is facing a major shift with the large-scale development of variable renewable energy sources (VRES). This vertical and centralized architecture helped the system to be robust and reliable. However, VRES production is intermittent and less predictable. As a result, the system needs to add more flexibility with new options such as Demand Side Management, storage technologies and VREs curtailment. But renewable energies potentials are unevenly distributed in Europe and, with high shares of VREs, power flows exchanges will increase between specific regions. As a result, the existing transmission grid would face congestions and these flexibility options might not be sufficient to alleviate these bottlenecks. To analyse these impacts, the work carried in this thesis uses the long-term energy model POLES (Prospective Outlook on Long-term Energy Systems) coupled with the new European power sector module EUTGRID (EUropean - Transmission Grid Investment and Dispatch). It includes a detailed transmission grid and more realistic power flows with a DC-OPF. A grid investment mechanism is also incorporated to determine the grid investments based on nodal prices. This new coupling permits to get a dynamic evolution of the transmission grid. The role of the transmission grid is being assessed and compared with other flexibility options. The grid investments increase largely with important development of VRES while other flexibility options cannot completely replace them. Finally, an exploratory work is being carried with the introduction of generic distribution grids (urban, semi-urban and urban) in EUTGRID. The results show that the reinforcements are slightly delayed with a greater use of back-up technologies which increases the total emissions
Supervision de sources de production d'électricité hybrides éolien/hydraulique dans les réseaux d'énergie interconnectés ou isolés by Mohamed Nasser( Book )

2 editions published in 2011 in French and held by 2 WorldCat member libraries worldwide

The concept of multi-sources system with an integrated and optimized power management and associated with several energy storage systems is seen as an important part of the answer to the issue of the randomness and fluctuation of dispersed wind power generation. In this context, it is interesting to combine two generation sources, wind and water. Water power generation is indeed likely to offset the randomness and fluctuation of wind power generation, because of its flexibility and availability. Generators and storage systems from a multi-source power plant can be located in different parts of the network but should be managed by a single industrial operator. Considering that the wind's issue is found at all levels of management time, it is necessary to establish a multi-level supervision of the considered integrated wind / hydro / storage central. Each stage is related to objectives and resources to define these requirements. However as the problem is vast, the work has focused mainly on two levels: "short-term" and "mid-term". The aim of this thesis is to propose methods for the management of wind / hydro / storage systems. Thus, ten supervisors are proposed according to different monitoring tools (fuzzy logic, optimization function...). Finally, the performance of these supervisors is compared using various indicators to quantify their contributions according to the objectives of different levels of supervision (power quality, energy efficiency)
Modular Multilevel Converter Control for HVDC Operation : Optimal Shaping of the Circulating Current Signal for Internal Energy Regulation by Gilbert Bergna Diaz( )

1 edition published in 2015 in English and held by 1 WorldCat member library worldwide

Following Europe's 2020 growth program, the Energy Roadmap 2050 launched by the European Commission (EC) has officially set a long term path for a low-carbon economy, assuming a reduction of at least 80% of greenhouse gas emissions by the year 2050. Meeting such ambitious requirements will imply a major change in paradigm, including the electricity grid infrastructure as we know it.The breakthroughs in semi-conductor technology and the advances in power electronics topologies and control have added momentum to the on-going process of turning the SuperGrid into a reality. Perhaps the most recent breakthrough occurred in 2003, when Prof. Marquardt introduced the Modular Multilevel Converter (MMC or M2C) which is now the preferred power electronic topology that is starting to be used in VSC-HVDC stations. It does however, introduce a number of rather complex challenges such as “additional” circulating currents within the converter itself, causing extra losses and potentially unstable operation. In addition, the MMC will be required to properly balance the capacitive energy stored within its different arms, while transferring power between the AC and DC grids that it interfaces.The present Thesis project aimed to design adequate “high-level” MMC control strategies suited for HVDC applications, under balanced and unbalanced AC grid conditions. The resulting control strategy is derived with a “top-to-bottom” design approach, inherent to optimization strategies, where the desired performance of the MMC results in the control scheme that will be applied. More precisely, the Lagrange multipliers optimization methodology is used to calculate the minimal MMC circulating current reference signals in phase coordinates, capable of successfully regulating the capacitive arm energies of the converter, while reducing losses and voltage fluctuations, and effectively decoupling any power oscillations that would take place in the AC grid and preventing them from propagating into the DC grid
Modélisation et commande d'un système de stockage d'énergie à base de supercondensateur pour l'hybridation des groupes électrogènes by Fayçal Bensmaine( )

1 edition published in 2014 in French and held by 1 WorldCat member library worldwide

The research in this thesis are part of study and control of a new concept of hybrid generator to reduce the power of the diesel engine (downsizing) in order to save fuel and improve the behavior of the synchronous generator during transients. The adopted solution is to place in parallel with the synchronous generator an energy storage system. The latter consists of an inverter with a super capacitor on the DC bus. The aim of the thesis was to scale the entire supercapacitor / static converter and to develop a control law having the best performance with the best compromise between the energy exchanged in the supercapacitor, efficiency, the group speed and voltage amplitude of the generator. A feedback control condition with integration of the deviation using LMI's approach has been established for the synthesis of loop current regulators from the inverter.A second control law was developed to regulate the variable voltage across the supercapacitor. A simulator combining generator and storage system has been developed to test these commands.All validations were made on an experimental test rig specifically developed for this thesis. The tests were conducted with an electric drive motor in the test platform of the LIAS and with a diesel in that of the Leroy Somer Motors company.Finally, experimental tests have highlighted the significant contribution of this hybridization on the diesel speed variationsand on the terminal voltage of the alternator during impact or load shedding
Frequency control coordination among non-synchronous AC areas connected by a multi-terminal HVDC grid. by Jing Dai( )

2 editions published in 2011 in English and held by 1 WorldCat member library worldwide

Cette thèse se focalise sur le problème du contrôle des flux de puissance entre plusieurs systèmes électriques AC non-synchrones reliés par un réseau à courant continu (DC). Elle propose trois schémas de commande afin de permettre aux sous-systèmes de partager leurs efforts de réglage de la fréquence et réduire ainsi le besoin de réserves propres et les coûts associés. A partir des mesures des fréquences de toutes les zones, le premier schéma de commande modifie les puissances injectées par chaque zone AC vers le réseau DC, de manière à faire réagir le système collectivement à des déséquilibres de charge. Cette réaction collective permet à chaque zone AC de réduire sa propre réserve primaire. Le deuxième schéma de commande a le même objectif que le premier, mais il agit sur les tensions continues des convertisseurs HVDC. En particulier, il modifie la tension continue de chaque convertisseur en fonction de la déviation de fréquence de la zone AC à laquelle il est connecté. Le dernier schéma de commande vise à rétablir les fréquences et les échanges de puissance à leurs valeurs nominales et prévues, respectivement, à la suite d'un déséquilibre. Il peut être combiné avec les deux autres schémas de commande. Des étudies théoriques démontrent les propriétés de stabilité des trois schémas de commande. Les résultats de simulation sur un réseau électrique de référence avec cinq zones AC illustrent leur bonne performance
 
moreShow More Titles
fewerShow Fewer Titles
Audience Level
0
Audience Level
1
  General Special  
Audience level: 0.93 (from 0.84 for Les groupe ... to 0.99 for Modélisat ...)

Languages
French (29)

English (6)