WorldCat Identities

Aptel, Florent (1979- ...)

Overview
Works: 37 works in 37 publications in 2 languages and 124 library holdings
Genres: Case studies 
Roles: Collector, Thesis advisor, Author, Opponent, Other
Publication Timeline
.
Most widely held works by Florent Aptel
Les myopies by David Gaucher( Book )

1 edition published in 2019 in French and held by 25 WorldCat member libraries worldwide

OCT en ophtalmologie : rapport 2019 by Société française d'ophtalmologie( Book )

1 edition published in 2019 in French and held by 22 WorldCat member libraries worldwide

Chirurgie des glaucomes by Jacques Laloum( Book )

1 edition published in 2016 in French and held by 19 WorldCat member libraries worldwide

Glaucome primitif à angle ouvert : rapport 2014 by Jean-Paul Renard( Book )

1 edition published in 2014 in French and held by 19 WorldCat member libraries worldwide

Etude en tomographie par cohérence optique de l'angle irido-cornéen et de la chambre antérieure : comparaison de l'OCT Visante et de l'OCT Casia by Aurélie Gimbert( Book )

1 edition published in 2013 in French and held by 2 WorldCat member libraries worldwide

Objectif : Comparer les différentes mesures de chambre antérieure obtenues avec un OCT spectral domain et un OCT time domain, et évaluer leur répétabilité. Méthodes : Etude prospective transversale condite sur des sujets sains. Le segment antérieur a été étudié avec un OCT spectral domain (Casia SS-100, Tomey, Nagoya Japon) et avec un OCT time domain (Visante, Zeiss Méditec, Dublin ÇA), sur un seul oeil de chaque sujet, choisi par randomisation. La pachymétrie centrale (CCT), la profondeur de chambre antérieure (ACD), la distance d'ouverture de l'angle à 500 µm et 750 µm (AOD 500 et AOD 750), la surface de séparation iridotrabéculaire à 500 µm et 750 µm (TISA 500 et TISA 750) et l'ouverture de l'angle à l'éperon scléral (SSA) ont été mesurés. Les coefficients de corrélation (ICCs) ont été calculés pour évaluer la répétailité des mesures. Nous avons utilisé le test de corrélation de Pearson pour évaluer la corrélation entre les mesures effectuées avec l'OCT Casia et celles effectuées avec le Visante. L'agrément entre les mesures a été évalué à l'aide d'un graphique de Bland-Altman. Résultats : 101 yeux de 101 sujets sains ont été analysés. Nous avons mis en évidence une excellente répétabilité avec le Casia et le Visante pour le CCT ( ICC 0,90-0,94 et 0,95-0,97 respectivement), l'ACD ( ICC 095-0,98 et 0,93-0,96 respectivement), l'AOD 500 ( ICC 0,92-0,96 et 0,90-0,94 respectivement), l'AOD 750 ( ICC 0,93-0,96 et 0,91-0,94 respectivement), le TISA 750 ( ICC 0,81-0,97 et 0,90-0,94 respectivement) et le SSA ( ICC 090-0,94 et 0,89-0,94 respectivement). Nous avons mis en évidence une bonne répétabilité avec le Casia et le Visante pour le TISA 500 ICC 0,68-0,97 et 0,70-0,93 respectivement). Les mesures obtenues avec le Casia et le Visante sont statistiquement significatives pour tous les paramètres étudiés 'r 0,76-0,98; p<0,06). Les ACD mesurés avec le Casia sont significativement plus larges que ceux mesurés avec le Visante (Différence 0,12 ±0,008 mm; p<0,0001) et les SSA mesurés avec le Casia sont significativement plus petits que ceux mesurés avec le Visante (différence 40,85 ± 5,3°; p<0,01). Conclusion: Les deux OCT Casia et Visante ont démontré leur excellente répétabilité. Excepté pour l'ACD et le SSA, les deux OCT ont un bon agrément en mesure de chambre antérieure et en mesure de l'angle irido-cornéen
Choroidal Thickness in Birdshot Retinochoroiditis Over a 2-Year Period by Raimondo Forte( )

1 edition published in 2018 in English and held by 2 WorldCat member libraries worldwide

Deposit of glass fragments during femtosecond laser penetrating keratoplasty by Valeria Nuzzo( )

1 edition published in 2008 in English and held by 2 WorldCat member libraries worldwide

Effects of glaucoma medications on long-term diurnal intraocular pressure variations by Georges Zaatar( )

1 edition published in 2015 in English and held by 2 WorldCat member libraries worldwide

Purpose: To evaluate the effects of glaucoma medications on the long-term diurnal intra-ocular pressure (IOP) variations in patients with primary open angle glaucoma (POAG).Design: Database analysis. Participants: One hundred forty-eight patients with POAG naïve from any glaucoma surgery and treated with a topical monotherapy of ocular hypotensive drug (beta-blocker, prostaglandin, carbonic anhydrase inhibitor or adrenergic agonist). Methods: We retrospectively reviewed the records of patients who underwent 3 diurnal IOP curve measurements 6 months apart with Goldmann aplanation tonometry recorded in the sitting position at 9 AM, 10 AM, 11 AM, Noon, 2 PM, 3 PM, 4 PM and 5 PM.Main outcome measures: Intervisit agreement of IOP by time point and of diurnal IOP curve parameters (mean, standard deviation, range, maximum, minimum, maximum hour, minimum hour) was assessed using the intraclass correlation coefficients (ICCs). When both eyes were eligible one eye was randomly chosen for analysis.Results: Sixty five patients were treated with prostaglandin analogs (PG), 38 with beta-blockers (BB), 23 with carbonic anhydrase inhibitor (CAI) and 22 with adrenergic agonists (AA). In all subjects with monotherapy, between-visit agreement of IOP values at each time point was generally poor, with ICCs ranging from 0.43 to 0.81 (3 time points out of 8 with ICCs > 0.75). In subjects treated with PG, we found better between-visit agreement of IOP values, with ICC ranging from 0.51 to 0.85 (6 time points out of 8 with ICCs > 0.75). In subjects treated with BB, CAI and AA, between-visit agreement of IOP values was generally poor, with ICCs ranging from 0.44 to 0.79 (3 time points out of 8 with ICCs > 0.75), from 0.51 to 0.78 (2 time points out of 8 with ICCs > 0.75), and from 0.29 to 0.77 (3 time points out of 8 with ICCs > 0.75), respectively. Conclusion: POAG patients with monotherapy usually do not manifest a repeatable diurnal IOP pattern from months to months. Only patients treated with PG exhibit better long-term repeatable diurnal IOP patterns
Ophtalmologie by Collège des ophtalmologistes universitaires de France( )

1 edition published in 2017 in English and held by 2 WorldCat member libraries worldwide

En parfaite conformité avec le nouveau DFASM (diplôme de formation approfondie en sciences médicales) s'inscrivant dans la R2C 2021, cet ouvrage rassemble l'ensemble des connaissances en Ophtalmologie. Il présente dans le détail la sémiologie oculaire puis les 16 items du programme relevant de la spécialité, avec des objectifs pédagogiques clairement définis, et comporte deux parties : • une partie Connaissances composée de 23 chapitres commençant systématiquement par un tableau de hiérarchisation des connaissances en rangs A et B, puis développant la thématique avec l'indication des rangs au fil du texte, étayée de points clés, tableaux et figures, de rubriques sur les notions à retenir et les situations de départ ; • une partie Entraînement qui propose des dossiers progressifs et des questions isolées (QRU/QRM) corrigés et commentés, offrant un outil performant d'autoévaluation. Cette 5e édition est une remise à jour complète de l'ensemble des données avec un approfondissement du GAFA. En phase avec les pratiques et recommandations les plus récentes, elle s'enrichit également de nouvelles illustrations et propose un accès à 10 vidéos inédites ainsi qu'à une banque d'images en ligne. Accédez à la banque d'images de cet ouvrage : l'ensemble des illustrations y sont regroupées et accessibles facilement via un moteur de recherche. Et retrouvez d'autres fonctionnalités. Le public Les étudiants en DFASM qui souhaitent se préparer efficacement aux ECNi et réussir leur DFASM, les médecins en formation non spécialisée et médecins généralistes qui trouveront ici les informations utiles pour leur pratique
Visual field defects of the contralateral eye of non-arteritic ischemic anterior optic neuropathy: are they related to sleep apnea? by Florent Aptel( )

1 edition published in 2017 in English and held by 2 WorldCat member libraries worldwide

Relationship between nocturnal intraocular pressure variations and sleep macrostructure by Perrine Canaud( )

1 edition published in 2015 in English and held by 1 WorldCat member library worldwide

Etude transversale conduite dans un centre de référence de chronobiologie. 12 sujets volontaires sains ont bénéficié d'un enregistrement en continu des variations de la PIO à l'aide d'une lentille de contact munie d'un micro capteur étudiant les changements de rayon de courbure cornéen corrélés à la PIO, pendant une période de 24 heures, sans réveil des sujets la nuit. Les principales caractéristiques du rythme nycthéméral de la PIO ont été évaluées lors des différentes phases du sommeil. Les variations de signal enregistrées par la lentille lors des variations de phases du sommeil ont été calculées pour évaluer les effets du sommeil sur la PIO. L'existence d'un rythme nycthéméral de la PIO a été retrouvée chez tous les sujets, avec une batyphase diurne et une acrophase nocturne. Durant la période nocturne, les valeurs de la PIO étaient significativement plus basses lors des phases de réveil que lors des phases de sommeil. Les valeurs de la PIO étaient significativement plus élevées pendant les phases de sommeil paradoxal que pendant les phases de sommeil lent léger et lent profond, et diminuaient progressivement avec le passage en sommeil profond. L'architecture du sommeil et les variations nocturnes de la PIO sont étroitement liées chez les sujets sains
Contribution à l'évolution d'un bioréacteur destiné à la recherche préclinique cornéenne et la conservation des greffons by Thibaud Garcin( )

1 edition published in 2019 in French and held by 1 WorldCat member library worldwide

La greffe de cornée a connu plusieurs évolutions, du cadre législatif de l'activité de prélèvement, aux indications et techniques chirurgicales. L'historique allogreffe fraîche a laissé place à l'eye banking permettant des contrôles qualité et sécurité pendant la conservation des greffons. L'hypothermie à 4°C ou l'organoculture, deux mondes de conservation passive diamétralement opposés, co-habitent depuis presque 50 ans, sans pouvoir apporter de solution optimale pour les patients. Dans un contexte de besoins croissants en greffons et d'une pénurie globale déjà importante, le laboratoire BiiGC a proposé un concept innovant : une conservation active grâce à un bioréacteur cornéen.Notre travail de thèse a différents objectifs : 1/ présenter l'état de l'art de la chaîne de la greffe de cornée ; 2/ décrire notre contribution à l'évolution de ce bioréacteur, comparé au gold standard l'organoculture, d'abord sur 1 mois puis sur 3 mois, démontrant sur une large série de cornées humaines, l' apport majeur du dispositif pour l'eye banking : plus de greffons disponibles et de meilleure qualité, une souplesse logistique plus importante pour les banques de cornées. L'industrialisation du bioréacteur prend donc tout son sens. Le bioréacteur préservant un état cornéen quasi in vivo jusqu'à 3 mois, ouvre le champ des possibles en utilisation préclinique ; 3/ rapporter l'activité nouvelle et spécifique réalisée par les coordonnateurs, avec un double rôle majeur pour l'activité de greffe et la recherche préclinique grâce aux dons ciblés, permettant des expérimentations avec des cornées fraîches comparables à celles greffées
Interaction laser femtoseconde et tissu cornéen : application à la découpe des greffons cornéens humains by Aurélien Bernard( )

1 edition published in 2013 in French and held by 1 WorldCat member library worldwide

Posterior lamellar graft, also named endothelial graft, consist in a replacement of a defective corneal endothelium by a healthy one take on a deceased donor. The epithelial and stromal layers of the patient stay untouched. A critical step of this technic is the preparation of the lamellar graft. Femtosecond lasers are better in comparison with microkeratome for low depth lamellar cut. However, femtosecond high depth corneal lamellar cuts show disappointing results. The aim of this thesis is to study and optimize corneal endothelial lamellar cuts, realized by microkeratome and femtosecond laser. Development of a corneal bioreactor and improve of corneal endothelial viability assessment are necessary for the realization of these objectives
Twenty-four-hour rhythm of ocular perfusion pressure in non-arteritic anterior ischaemic optic neuropathy( )

1 edition published in 2014 in English and held by 1 WorldCat member library worldwide

Abstract Purpose In non-arteritic anterior ischaemic optic neuropathy (NAAION) patients, circulatory insufficiency within the optic nerve has previously been hypothesized to be related to nocturnal systemic hypotension. The main objective of this prospective cohort study was to investigate the nyctohemeral variations in ocular perfusion pressure (OPP) in NAAION patients. Methods In 20 patients with NAAION, the intraocular pressure (IOP) was measured using the Tono-Pen XL™ electronic tonometer every hour for 24hr. Blood pressure (BP) was evaluated over 24hr. Mean OPP was calculated with the following formula: OPP sitting position=(0.74×mean BP) − IOP and OPP lying position=(0.84×mean BP) − IOP. A nonlinear least squares dual-harmonic regression analysis approach was used to model the 24-hr rhythms of OPP data. Results On average, a 24-hr amplitude of 4.7±2.6mmHg was found for OPP. The patients were classified as either having a diurnal OPP rhythm (i.e. with a diurnal acrophase, 10% of the cases), a nocturnal OPP rhythm (45%) or absence of OPP rhythm (45%). Four patients had a nocturnal reduction in OPP (mean, −11%). Conclusion The physiological nocturnal rhythm of OPP was maintained in 45% of the NAAION patients. The nocturnal reduction in OPP seen in 20% of the patients was within the range of OPP where optic nerve blood flow autoregulation is still fully operative. A high prevalence of obstructive sleep apnoea syndrome in our population (71%) may explain the low frequency of systemic nocturnal hypotension
Analyse de l'activité de la chirurgie vitréo-rétinienne en France metropolitaine en 2016 by Mehdi Tadjine( )

1 edition published in 2019 in French and held by 1 WorldCat member library worldwide

Introduction : La demande en soins ophtalmologiques augmente car de nombreuses pathologies oculaires sont liées à l'âge. Il n'y a pas d'état des lieux récent des pratiques ophtalmologiques en France. L'objectif de ce travail est de décrire l'activité chirurgicale concernant la chirurgie du segment postérieur par département en France métropolitaine sur l'année 2016. Matériel et méthodes : Nous avons extrait les données de la base du Système National des Données de Santé (SNDS) en analysant les actes de la Classification Commune des Actes Médicaux (CCAM) correspondant à la chirurgie vitréo-rétinienne chez les patients de plus de 20 ans en 2016. Les analyses ont été faites pour les chirurgiens libéraux et les hôpitaux réalisant 50 actes et plus par an. Pour chaque département ont été calculés le nombre d'actes réalisés, le nombre de chirurgiens, l'âge moyen de ceux réalisant la majeure partie de l'activité. Résultats : On dénombre 65492 actes de chirurgie du segment postérieur, au total, chez la population âgée de 20 ans et plus. On dénombre 37 départements sans aucun chirurgien réalisant plus de 50 actes. L'activité est réalisée par 369 ophtalmologistes surspécialisés d'âge moyen 43,8 ans. L'âge moyen des ophtalmologistes réalisant le plus d'actes (4ème quartile d'activité) est de 47.6 ans. Discussion : Il existe des disparités importantes en termes de densités de praticiens et d'interventions sur le territoire. Conclusion : Ce travail est actuellement poursuivi pour les autres surspécialités de l'ophtalmologie afin de prévoir les besoins en formation des internes en ophtalmologie. Les capacités de formation futures devront être adaptées à l'aune de ces données
Treatment of refractory open-angle glaucoma using ultrasonic circular cyclocoagulation : a prospective case series by Caroline Dupuy( )

1 edition published in 2014 in English and held by 1 WorldCat member library worldwide

Objective: To evaluate the efficacy and safety of the Ultrasonic Circular Cyclo Coagulation (UC3) procedure in patients with refractory primary open-angle glaucoma. Material and methods: Prospective non-comparative interventional case series performed in 2 French glaucoma centers. 28 eyes with primary open-angle glaucoma, intraocular pressure (IOP) > 21 mmHg, failed previous surgeries and hypotensive medications were insonified with a therapy probe comprising 6 piezoelectric transducers. The 6 transducers were activated with a 6 seconds exposure time. Ophthalmic examinations were performed before the procedure, and at 1 day, 1 week, 1, 2, 3, 6 and 12 months after. Primary outcomes were surgical success (defined as IOP reduction from baseline ≥ 20% and IOP > 5mmHg) at the last follow-up visit, and vision-threatening complications. Secondary outcomes were mean IOP at each follow-up visit compared to baseline, medication use, complications, and re-interventions. Results: IOP was significantly reduced (p<0.05), from a mean preoperative value of 29.0 ± 7.2 mmHg to a mean value of 21.6 ± 9.4 mmHg at last follow-up (mean IOP reduction of 26%). Complete success (IOP reduction >20% without re-intervention and without hypotensive medications adjunction) was achieved in 50% of eyes at last follow-up (mean IOP reduction of 45% in these same eyes) and qualified success (IOP reduction >20% with possible re-interventions) was achieved in 68% of eyes at last follow-up. No major intra- or post-operative complications occurred. Conclusions: UC3 procedure seems to be an effective and well-tolerated method to reduce intraocular pressure in patients with primary open-angle glaucoma
Progression of visual field in patients with primary open-angle glaucoma - ProgF study 1( )

1 edition published in 2015 in English and held by 1 WorldCat member library worldwide

Abstract: Purpose: To evaluate the visual field rate of progression of patients with treated ocular hypertension (OHT) and primary open-angle glaucoma (POAG) in clinical practice, using the mean deviation (MD) and the visual field index (VFI). Methods: Non-interventional cohort study. From a large multicentre database representative of the French population, 441 eyes of 228 patients with treated OHT or POAG followed up at least 6years with Humphrey 24.2 Sita-Standard visual field examination at least twice a year were identified. From initial data, eyes were classified in five groups: 121 with OHT, 188 with early glaucoma (MD greater than −6dB), 45 with moderate glaucoma (MD −6 to −12dB), 41 with advanced glaucoma (MD −12 to −18dB) and 46 with severe glaucoma (MD less than −18dB). Rate of progression during the follow-up period was calculated using the trend analysis of the Guided Progression Analysis software. Results: The mean duration of follow-up was 8.4±2.7years and the mean number of visual field, 18.4±3.5. In eyes with OHT, rate of progression was −0.09dB/year (−0.17%VFI/year). In eyes with POAG, rate of progression was −0.32dB/year (−0.83%VFI/year) in eyes with early glaucoma, −0.52dB/year (−1.81%VFI/year) in moderate glaucoma, −0.54dB/year (−2.35%VFI/year) in advanced glaucoma and −0.45dB/year (−1.97%VFI/year) in severe glaucoma. In eyes with POAG, a significant progression (p<0.05) was detected in 159 of 320 eyes (49.7%) with trend analysis and 117 of 320 eyes (36.6%, likely progression) or 183 of 320 eyes (57.2%, possible and likely progression) with event analysis. Conclusions: Primary open-angle glaucoma is a progressive disease in the majority of patients despite cautioned treatment and follow-up. The rate of progression varies greatly among subjects
Predictive factors of intraocular pressure and visual field progression change after therapeutic escalation in patients with glaucoma by Olivier Gavard( )

1 edition published in 2017 in English and held by 1 WorldCat member library worldwide

To evaluate the effect of therapeutic escalation on the rate of patients with a visual field progression, and the potential predictive factors of intra ocular pressure (IOP) and visual field progression, in clinical practice.In a multicenter database study, from four French glaucoma centers, we reviewed the electronic records of 225 patients, suffering from glaucoma, who underwent five consecutive visits 6 month apart, before and after medical treatment escalation, additive laser trabeculoplasty or filtering surgery. Patients benefited of an ophthalmic examination with visual field tests. There were 212 subjects with open angle glaucoma. After the therapeutic escalation, there was a significant decrease from 24.5% to 13.7% of the ratio of patients with visual field progression, with an average visual field loss of -0.5 dB/years to -0.32 dB/years. Mono therapy to triple therapy led to a decrease of the ratio from 58% to 41%. Strengthening medical treatment with the addition of hypotensive therapy, was significantly associated, during all the follow-up, with a lower IOP. In multivariable analysis, only male gender and higher age were significantly associated with a lower mean IOP, with respectively -1.49 mmHg and -0,63mmHg every ten years of age. Concerning visual field progression, no predictive factor was found. Therapeutic escalation led to a significant decrease of IOP and the rate of patients with a visual field progression. An increase in the number of patients included and duration of the study could allow to identify additional predictive factors
Applications des ultrasons focalisés de haute intensité au traitement du glaucome by Florent Aptel( )

1 edition published in 2011 in French and held by 1 WorldCat member library worldwide

Le glaucome est une pathologie fréquente principalement due à une élévation de la pression intraoculaire. La pression intraoculaire est le fruit d'un équilibre entre la production du liquide qui remplit la portion antérieure de l'œil - l'humeur aqueuse - et son élimination. Les traitements du glaucome peuvent donc agir selon deux mécanismes : la réduction de la production d'humeur aqueuse par la destruction partielle ou l'inhibition pharmacologique du corps ciliaire, structure responsable de la production de l'humeur aqueuse, ou la facilitation de l'évacuation de l'humeur aqueuse en dehors de l'oeil. De nombreuses méthodes physiques peuvent être utilisées pour détruire le corps ciliaire : lasers, cryothérapie, micro-ondes, etc. Néanmoins, toutes ces méthodes ont deux inconvénients majeurs qui limitent leur utilisation : elles sont peu sélectives de l'organe à traiter, entraînant souvent des dommages des structures adjacentes, et elles présentent une relation effet-dose très inconstante, empêchant de prévoir avec précision l'effet du traitement. L'objectif de ce travail de thèse est le développement d'un dispositif ultrasonore de coagulation du corps ciliaire circulaire, comprenant 6 transducteurs piézoélectriques en forme de segments de cylindre, et générant 6 lésions segmentaires s'inscrivant dans un anneau de diamètre similaire à celui formé par le corps ciliaire. Les expérimentations animales ont montré une nécrose de coagulation sélective des zones du corps ciliaire traitées par le dispositif. Le premier essai clinique a montré que cette méthode était bien tolérée et permettait une réduction importante, prédictible et maintenue dans le temps de la pression intraoculaire
Observance thérapeutique et qualité d'instillation des collyres chez les patients atteints de glaucome chronique ou d'hypertonie intra-oculaire by Florent Aptel( Book )

1 edition published in 2009 in French and held by 1 WorldCat member library worldwide

 
moreShow More Titles
fewerShow Fewer Titles
Audience Level
0
Audience Level
1
  Kids General Special  
Audience level: 0.93 (from 0.86 for Ophtalmolo ... to 0.97 for Glaucome p ...)

Alternative Names
Florent Aptel wetenschapper

Languages
French (10)

English (10)